Filter Results By:

Products

Applications

Manufacturers

Showing results: 1246 - 1260 of 1604 items found.

  • Programmable/Direct Reading Attenuators

    ERAVANT

    Is a dual function direct reading and programmable rotary vane type attenuator for use in millimeterwave systems across the standard WR-03 frequency range of 220 to 330 GHz. The attenuator is an ideal piece of equipment in waveguide systems where a broad direct reading of attenuation is required. The default mode of operation is manual direct reading. In manual mode, the attenuation is adjustable with the large knob and the digital LCD screen displays the current attenuation value. The LCD screen is powered by an internal rechargable battery, which is charged via the 2.5mm DC jack by a provided DC to AC adapter. The 2.5mm DC jack also provides power to the stepper motor, encoder and internal microprocessor for the programmable mode function. The user can quickly switch to programmable mode by connecting the powered-up attenuator to a computer with the USB Type B port. In programmable mode, the attenuation is finely adjusted with a precision stepper motor by the internal microprocessor via user-entered serial port commands from the computer.

  • Compact Receiver

    UCR401 - Lectrosonics, Inc.

    The UCR401 is a high performance compact UHF wireless microphone receiver for mobile applications such as ENG and film production. The compact size, battery and external power and rugged attached antennas are ideal for video camera mounted use. Unique DSP algorithms in the design provide full compatibility with all Lectrosonics 400 Series Digital Hybrid Wireless™ transmitters and variety of analog transmitters from Lectrosonics and some other manufacturers. Power is provided by two AA batteries, typically NiMH rechargeable types, or external DC supplied via a jack on the rear panel.

  • Refrigerant Leak Detector

    KM 310 / KM 312 - Kusam Electrical Industries Limited

    • LED Tip Light• Mute Function• Low battery indication• LED power indicator• Sensor failure indicator (KM 312)• Start-up melody (KM 312)• USB power adaptor (KM 312)• Rugged flexible probe• 3 adjustable sensitivity levels• DC 3.7V rechargeable lithium battery (KM 312)• Multiple colors LED for leak level indicator• Extremely sensitive heated diode sensor• Automatic adjustment & reset to background (KM 312)• Detects R-134a, R-410a, R-407c & R-22 etc.• Microcontroller circuitry that guarantees accuracy & reliability

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix

    40-552-002 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-011 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-012 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Aspirated Radiation Shield

    Apogee Instruments, Inc.

    The fan has an ingress protection (IP) rating of 55, virtually eliminating moisture and dust ingress. At full speed the power requirement is 1 W (80 mA at 12 V DC). To conserve power fan speed can be reduced, via pulse width modulation (PWM), to 0.3 W at night or when wind speed is greater than 3 m s-1 without loss of accuracy. If the fan is continuously operated at full speed lifetime is rated at 50,000 hours (5.7 years). The fan includes a tachometer, allowing RPM to be mounted to detect obstruction of the fan.

  • Board

    Arduino Mega 2560 Rev3 - Arduino llc

    The Arduino Mega 2560 is a microcontroller board based on the ATmega2560. It has 54 digital input/output pins (of which 15 can be used as PWM outputs), 16 analog inputs, 4 UARTs (hardware serial ports), a 16 MHz crystal oscillator, a USB connection, a power jack, an ICSP header, and a reset button. It contains everything needed to support the microcontroller; simply connect it to a computer with a USB cable or power it with a AC-to-DC adapter or battery to get started. The Mega 2560 board is compatible with most shields designed for the Uno and the former boards Duemilanove or Diecimila.

  • PXI 8x4 Power Matrix, 2 Pole

    40-550-002 - Pickering Interfaces Ltd.

    Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current. These modules are fitted with electro-mechanical power relays, gold-flash over silver alloy. A spare relay is built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix

    40-552-001 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Power Cable Fault Locator

    TM500  - T&M Tools Limited Co

    TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.

  • POWER PROBE MAESTRO

    PPTM01AS - Matco Tools

    *Connects with the new Power Probe Tek application for greater diagnostic functionality*The Maestro and Power Probe Tek App will be compatible to connect with a majority of diagnostic scan tools*Trace mode offers scope-like functionality*Stream and record visual traces of electrical issues found when diagnosing*DC voltmeter with the capability of applying battery supplied voltage or ground*AC voltmeter: TRMS, peak-to-peak/min/max, frequency, duty cycle*Resistance testing with a live or unloaded circuit*Fuel-injector test mode*Driver test for testing module drivers

  • High Power Programmable AC Source

    61610 - Chroma Systems Solutions, Inc.

    Power Rating:61511/61611: 12KVA61512/61612: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • Electrical Calibrators

    Fluke Calibration

    An electrical calibrator, or dc calibrator from Fluke Calibration includes many innovative and multi-functional solutions to help laboratories operate efficiently, increase throughput, and comply with today’s quality standards. Versatile models and options provide a wide range of possibilities to match a variety of workloads and budgets. Electrical calibrators include: Multi-product calibrators; multifunction calibrators; oscilloscope calibrators; power calibrators; pressure/temperature calibrators.

  • Linear Signal Splitters

    Advanced Science and Novel Technology, Co., Inc.

    DC to 25GHz broadband linear signal splitterOne differential CML-type input port and four phase-matched differential CML-type output portsDifferential input linearity range up to 1000mV p-pDifferential gain of approximately -1.5dBLow jitter and limited temperature variation over industrial temperature rangeSingle +3.3V or -3.3V power supplyPower consumption: 1.35WFabricated in SiGe for high performance, yield, and reliabilityCustom CQFP 44-pin package

Get Help